Comparison of Volumetric Modulated Arc and Three-Dimensional Conformal Radiation Therapy in Patients with Rectal Cancer
|
H Taher Jhangeer * , F Fatihalla Hassan  |
| 1.Department of Pharmacology and Medical Physics and Clinical Biochemistry, College of Medicine, Hawler Medical University, Erbil, Iraq. , halimajihangir@gmail.com |
|
|
Abstract: (23 Views) |
Background and Objective: Radiotherapy is a key component in the multimodal treatment of rectal cancer. With technological advances, Volumetric Modulated Arc Therapy (VMAT) has been introduced as a potential alternative to Three-Dimensional Conformal Radiation Therapy (3DCRT), offering improved precision in dose delivery. This study aims to compare the dosimetric outcomes of VMAT and 3D-CRT in rectal cancer patients.
Methods: The present cross-sectional study was conducted on 20 patients with rectal cancer (15 males and 5 females). For each patient, two treatment plans were generated—VMAT and 3DCRT—using a prescribed dose of 5040 cGy. Dosimetric parameters, including minimum, maximum, and mean doses, planning target volume (PTV) coverage, conformity index (CI), and homogeneity index (HI), were assessed using dose–volume histograms (DVH). Organ-at-risk (OAR) doses and overall plan quality were also evaluated.
Findings: Both techniques achieved comparable planning target volumes (mean PTV ≈ 489 cm³). VMAT demonstrated superior dose conformity and homogeneity, reflected by a higher conformity index (CI: 0.999 vs. 0.979) and a lower homogeneity index (HI: 0.049 vs. 0.092). Regarding target coverage, VMAT achieved a higher proportion of the PTV receiving 95% of the prescribed dose (V95: 98.6% vs. 96.9%), with improved dose uniformity as shown by lower D2% (52.1 Gy vs. 53.4 Gy) and higher D98% (49.2 Gy vs. 48.1 Gy). Regarding OARs, VMAT resulted in more favourable DVH endpoints. The bladder volume receiving ≥ 50 Gy (V50) was significantly reduced with VMAT (38% vs. 46%), while bowel sparing was also improved (V45: 21% vs. 29%). Similarly, femoral head exposure was lower, particularly for the right femoral head, where the volume receiving ≥ 40 Gy was reduced (12% vs. 24%).
Conclusion: The results of this study demonstrated that VMAT offers better PTV coverage and OAR sparing than 3DCRT, supporting its use as a more effective technique for rectal cancer radiotherapy. |
Article number: e64 |
| Keywords: Radiotherapy, Rectal Cancer, VMAT, 3DCRT, Organs at Risk. |
|
|
Full-Text [PDF 785 kb]
(12 Downloads)
|
Type of Study: Research |
Subject:
Radiobiology Received: 2025/07/18 | Accepted: 2025/09/14 | Published: 2026/11/17
|
|
|
|
|
|
|
| Send email to the article author |
|
|