<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Journal of Babol University of Medical Sciences</title>
<title_fa>مجله علمی دانشگاه علوم پزشکی بابل</title_fa>
<short_title>J Babol Univ Med Sci</short_title>
<subject>Medical Sciences</subject>
<web_url>http://jbums.org</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>1561-4107</journal_id_issn>
<journal_id_issn_online>2251-7170</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi>10.22088/jbums</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid></journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science></journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1396</year>
	<month>4</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2017</year>
	<month>7</month>
	<day>1</day>
</pubdate>
<volume>19</volume>
<number>7</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>بهینه‌سازی کیفیت تصویر و دُز بیمار در تصویربرداری قفسه سینه با دستگاه پرتونگاری دیجیتال </title_fa>
	<title>Optimization of Image Quality and Patient Dose in Digital Radiography of the Chest
</title>
	<subject_fa>فیزیک پزشکی</subject_fa>
	<subject>Medical Physics</subject>
	<content_type_fa>تجربی</content_type_fa>
	<content_type>Experimental</content_type>
	<abstract_fa>&lt;p dir=&quot;RTL&quot; style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;font-family:times new roman;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;color:blue;&quot;&gt;&lt;span style=&quot;font-size:10.0pt;&quot;&gt;سابقه و هدف:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt; &lt;span style=&quot;font-size:10.0pt;&quot;&gt;در بخش&#8204;های پرتوشناسی تشخیصی، به طور روزافزون دستگاه&#8204;های پرتونگاری دیجیتال جایگزین دستگاه&#8204;های پرتونگاری فیلم-اسکرین می&#8204;شوند. علی&#8204;رغم تفاوت در ویژگی&#8204;های آشکارسازهای جدید ثبت تصاویر، همان پروتکل&#8204;های پرتونگاری که برای سامانه&#8204;های فیلم-اسکرین بکار گرفته می&#8204;شد همچنان بدون بازنگری ویژه&#8204;ای برای دستگاه&#8204;های دیجیتال نیز بکار می&#8204;روند. در این پژوهش، کیفیت تصویر و دُز بیمار در تصویربرداری دیجیتال از قفسه سینه مورد بررسی و بهینه&#8204;سازی قرار گرفتند.&lt;/span&gt;&lt;br&gt;
&lt;strong&gt;&lt;span style=&quot;color:blue;&quot;&gt;&lt;span style=&quot;font-size:10.0pt;&quot;&gt;مواد و روش&amp;shy;ها:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt; &lt;span style=&quot;font-size:10.0pt;&quot;&gt;در این مطالعه تجربی از دو دستگاه پرتونگاری دیجیتال &lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;&lt;span style=&quot;font-size:10.0pt;&quot;&gt;Shimadzu, RDA Speed&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-size:10.0pt;&quot;&gt; و &lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;&lt;span style=&quot;font-size:10.0pt;&quot;&gt;Siemens, G2107&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-size:10.0pt;&quot;&gt; استفاده شده است. در فواصل مختلف چشمه تا فانتوم و با کیلوولتاژهای مختلف، تصویربرداری و اندازه&#8204;گیری دُز انجام گرفت. برای اندازه&#8204;گیری کیفیت تصویر در این مطالعه، فانتوم بررسی جزئیات- کنتراست بکار گرفته شد. برای بررسی بهینه&#8204;سازی، از پارامتر نسبت کیفیت تصویر به مجذور دُز بیمار (&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;&lt;span style=&quot;font-size:10.0pt;&quot;&gt;IQF&lt;sub&gt;inv&lt;/sub&gt;/E&lt;sup&gt;2&lt;/sup&gt;&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-size:10.0pt;&quot;&gt;) استفاده گردید.&lt;/span&gt;&lt;br&gt;
&lt;strong&gt;&lt;span style=&quot;color:blue;&quot;&gt;&lt;span style=&quot;font-size:10.0pt;&quot;&gt;یافته&amp;shy; ها:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt; &lt;span style=&quot;font-size:10.0pt;&quot;&gt;بررسی پارامت&lt;span style=&quot;color:black;&quot;&gt;رهای &lt;/span&gt;اندازه&#8204;گیری شده برای بهینه&#8204;سازی نشان داد که در هر دو دستگاه با کاهش اندازه کیلوولتاژ علی&#8204;رغم افزایش دُز موثر بیمار، نسبت &lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;&lt;span style=&quot;font-size:10.0pt;&quot;&gt;IQF&lt;sub&gt;inv&lt;/sub&gt;/E&lt;sup&gt;2&lt;/sup&gt;&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-size:10.0pt;&quot;&gt; نیز افزایش می&#8204;یابد. بیشترین اندازه این نسبت برای دستگا&lt;span style=&quot;color:black;&quot;&gt;ه&#8204;&lt;/span&gt;های &lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;&lt;span style=&quot;font-size:10.0pt;&quot;&gt;Shimadzu, RDA Speed&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-size:10.0pt;&quot;&gt; و &lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;&lt;span style=&quot;font-size:10.0pt;&quot;&gt;Siemens, G2107&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-size:10.0pt;&quot;&gt; بترتیب برابر 0/180 و 0/0083 اندازه&#8204;گیری گردید.&lt;/span&gt;&lt;br&gt;
&lt;strong&gt;&lt;span style=&quot;color:blue;&quot;&gt;&lt;span style=&quot;font-size:10.0pt;&quot;&gt;نتیجه&amp;shy; گیری:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt; &lt;span style=&quot;font-size:10.0pt;&quot;&gt;یافته&#8204;های این پژوهش نشان داد که با افزایش کیلوولتاژ نسبت کیفیت تصویر به دُز بیمار کاهش پیدا می&#8204;کند. بنابراین برای بهینه&#8204;سازی تصویربرداری از قفسه سینه بایستی، تا جای ممکن اندازه کیلوولتاژ را با توجه به جثه بیمار و هدف بالینی مورد نظر کاهش داد.&amp;nbsp;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&amp;nbsp;&lt;/p&gt;
</abstract_fa>
	<abstract>&lt;p dir=&quot;ltr&quot; style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;font-family:times new roman;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;color:blue;&quot;&gt;&lt;span style=&quot;font-size:10.0pt;&quot;&gt;BACKGROUND AND OBJECTIVE:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt; &lt;span style=&quot;color:black;&quot;&gt;&lt;span style=&quot;font-size:10.0pt;&quot;&gt;Digital systems have been replacing with screen-film analogue systems in diagnostic radiology departments, rapidly. Despite the differences in the properties of new x-ray imaging detectors, the same radiographic protocols that had been used for radiographic film-screen are used for digital imaging systems, without any review yet. In this study, the image quality and the patient dose in digital imaging of the chest are evaluated and optimized.&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;strong&gt;&lt;span style=&quot;color:blue;&quot;&gt;&lt;span style=&quot;font-size:10.0pt;&quot;&gt;METHODS:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt; &lt;span style=&quot;color:black;&quot;&gt;&lt;span style=&quot;font-size:10.0pt;&quot;&gt;Two digital radiography machines from two separated hospitals (Imam Khomeini and Bu Ali Hospitals-Sari) have been used in this experimental research. Imaging and dose measurement are carried out at different source to phantom distances and kilo-voltages. For measurement of the image quality, a contrast-detail radiography (CDRAD) phantom is used. For evaluation of optimization, the Inverse Image Quality Figure per patient dose squared (&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;color:black;&quot;&gt;&lt;span style=&quot;font-size:10.0pt;&quot;&gt;IQF&lt;sub&gt;inv&lt;/sub&gt;/E&lt;sup&gt;2&lt;/sup&gt;&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;color:black;&quot;&gt;&lt;span style=&quot;font-size:10.0pt;&quot;&gt;) is used.&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;strong&gt;&lt;span style=&quot;color:blue;&quot;&gt;&lt;span style=&quot;font-size:10.0pt;&quot;&gt;FINDINGS:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;span style=&quot;color:black;&quot;&gt;&lt;span style=&quot;font-size:10.0pt;&quot;&gt; Evaluation of measured data for optimization shows that for both of these two digital radiography machines, despite of increasing in patent dose, with reducing of kilo-voltage, the &lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;color:black;&quot;&gt;&lt;span style=&quot;font-size:10.0pt;&quot;&gt;IQF&lt;sub&gt;inv&lt;/sub&gt;/E&lt;sup&gt;2 &lt;/sup&gt;is increased. The maximum values of this parameter for &lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;color:black;&quot;&gt;&lt;span style=&quot;font-size:10.0pt;&quot;&gt;Imam Khomeini and Bu Ali Hospitals are measured 0.0180 and 0.0083, respectively.&amp;nbsp; &lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;strong&gt;&lt;span style=&quot;color:blue;&quot;&gt;&lt;span style=&quot;font-size:10.0pt;&quot;&gt;CONCLUSION:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt; &lt;span style=&quot;color:black;&quot;&gt;&lt;span style=&quot;font-size:10.0pt;&quot;&gt;The results of this study indicate that despite the traditional notion of using higher kilo-voltages for chest radiography, with increasing kilo-voltage, the ratio of image quality per patient dose is reduced. So, for optimization of chest radiography, as much as possible the kilo-voltage should be reduced based on the size of patient and clinical purpose.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;
</abstract>
	<keyword_fa>پرتونگاری دیجیتال, تصویربرداری قفسه سینه, فانتوم‌ جزئیات-کنتراست, بهینه‌سازی</keyword_fa>
	<keyword>Digital radiography, Chest radiography, Contrast-Detail Phantom, Optimization</keyword>
	<start_page>57</start_page>
	<end_page>62</end_page>
	<web_url>http://jbums.org/browse.php?a_code=A-10-721-1&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>R</first_name>
	<middle_name></middle_name>
	<last_name>Paydar</last_name>
	<suffix></suffix>
	<first_name_fa>رضا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>پایدار</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>paydar57@gmail.com</email>
	<code>100319475328460026367</code>
	<orcid>100319475328460026367</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Radiation Sciences, Faculty of Allied Medicine, Iran University of Medical Sciences, Tehran, I.R.Iran</affiliation>
	<affiliation_fa>گروه علوم پرتوی، دانشکده پیرا پزشکی، دانشگاه علوم پزشکی ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>SH</first_name>
	<middle_name></middle_name>
	<last_name>Mousavie Anijdan</last_name>
	<suffix></suffix>
	<first_name_fa>سید حسین</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>موسوی انیجدان</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>shmosavia@mubabol.ac.ir</email>
	<code>2062373252</code>
	<orcid>100319475328460026368</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Department of Radiation Technology, Allied Medicine Faculty, Babol University of Medical Sciences, Babol, I.R.Iran</affiliation>
	<affiliation_fa>گروه تکنولوژی پرتوها، دانشکده پیراپزشکی، دانشگاه علوم پزشکی بابل</affiliation_fa>
	 </author>


	<author>
	<first_name>A</first_name>
	<middle_name></middle_name>
	<last_name>Khorrami Moghaddam</last_name>
	<suffix></suffix>
	<first_name_fa>علیرضا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>خرمی مقدم</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>a.khorrami@mazums.ac.ir</email>
	<code>100319475328460026369</code>
	<orcid>100319475328460026369</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Radiology, Allied Medicine Faculty, Mazandaran University of Medical Sciences, Sari, I.R.Iran</affiliation>
	<affiliation_fa>گروه رادیولوژی، دانشکده پیراپزشکی، دانشگاه علوم پزشکی مازندران</affiliation_fa>
	 </author>


	<author>
	<first_name>I</first_name>
	<middle_name></middle_name>
	<last_name>Mohammadi</last_name>
	<suffix></suffix>
	<first_name_fa>ایرج</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>محمدی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>imohammadi@farabi.tums.ac.ir</email>
	<code>2063724271</code>
	<orcid>100319475328460026370</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Basic Sciences, Faculty of Medicine, Sari Branch, Islamic Azad University, Sari, I.R.Iran</affiliation>
	<affiliation_fa>گروه علوم پایه، دانشکده پزشکی، واحد ساری، دانشگاه آزاد اسلامی</affiliation_fa>
	 </author>


	<author>
	<first_name>R</first_name>
	<middle_name></middle_name>
	<last_name>Reiazi</last_name>
	<suffix></suffix>
	<first_name_fa>رضا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>ریاضی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>reiazi.r@iums.ac.ir</email>
	<code>100319475328460026371</code>
	<orcid>100319475328460026371</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Medical Physics, School of Medicine, Iran University of Medical Sciences, Tehran, I.R.Iran</affiliation>
	<affiliation_fa>گروه فیزیک پزشکی، دانشکده پزشکی، دانشگاه علوم پزشکی ایران</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
